Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

Product Details
Customization: Available
After-sales Service: Dedicated After-Sales Service Department
Warranty: 12 Months
Still deciding? Get samples of US$ 175000/Piece
Request Sample
Manufacturer/Factory, Trading Company
Diamond Member Since 2022

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Registered Capital
21000000 RMB
Plant Area
101~500 square meters
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Find Similar Products
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
P1250-1
Type
Self-Starting Diesel Generator
Installation Method
Fixed
Stroke
Four Stroke
Cooling Method
Water Cooling
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Voltage, Frequency
400/230 V, 50 Hz
Weight
Dry: 7137 (15734) Kg / Wet: 7250 (15983) Kg
Engine Make
Perkins
Circuit Breaker Type: 3 Pole MCB
Options Available
Transport Package
Shipping Containers
Specification
L4789 (188.5)mm*W2197 (86.5)mm*H2069 (81.5)mm
Trademark
FG WILSON
Origin
China
Production Capacity
50000

Product Description

 

Wilson Advantage

1.Product advantages
*Start-up performance: It takes 5 seconds to reach a stable state after starting the cranking, and it takes about 15 seconds to reach full load.
*Loading capacity:
One-step loading capacity exceeds 50%

*Power density:High power density, small unit size
*Maintenance of the economy:Some parts of the 720-2000kw unit are interchangeable to reduce costs - the advantage of the high power section
*Extended warranty service:60-month extended warranty service


2.service advantage
*Customized services Wilson has a solution team of more than 200 people to design and produce customized products according to customers' special needs.
*Advanced control and parallel system

*Remote cooling device
*Emission silencer system
*Rainproof and anti-speaker box
*High insulation level
*Customized testing
 

3. Complete solution-pre-sales support:
*Equipment load calculation and generator set selection: According to the project equipment load requirements, calculate the actual power supply demand, taking into account reliability and economy;
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

*
Deepening of the engine room design: Based on project requirements and actual site conditions, deepen the diesel engine room design plan and provide professional suggestions; including diesel engine load-bearing foundation, engine room ventilation system, oil system, cable bridge, distribution cabinet layout, diesel engine room Hoisting etc.


4. Complete solution-after-sales support
*Provide professional product training
*FG Wilson Original Parts Consulting Help
*Ensure timely supply and delivery of parts
*Complete warranty, extended warranty and customer service agreements


Product certification and qualifications
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
P1250-1 model product details
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Engine Make   Perkins
Engine Model:   4008-30TAG3
Alternator Make   Leroy Somer
Alternator Model:   LL8224H
Control Panel:   DSE7410
Base Frame:   Heavy Duty Fabricated Steel
Circuit Breaker Type:   Options Available
Frequency:   50 HZ 60 HZ
Engine Speed: RPM rpm 1500  
Fuel Tank Capacity: litres (USgal) N/A (N/A)
Fuel Consumption Prime litres (USgal)/hr 240.1 (63.4)  
Fuel Consumption Standby litres (USgal)/hr 266.3 (70.3)  
 
Engine Technical Data
No. of Cylinders
Alignment
Cycle
Bore
Stroke
Induction
Cooling Method
Governing Type
Governing Class
Compression Ratio
Displacement
Moment of Inertia:
Voltage
Ground
Battery Charger Amps
Engine Weight Dry
Engine Weight Wet



mm (in)
mm (in)






L (cu. in)
kg  (lb/in²)



kg (lb)
kg (lb)
8
IN LINE
4 STROKE
160 (6.3)
190 (7.5)
TURBOCHARGED
WATER
ELECTRONIC
ISO 8528
13.0:1
30.6 (1867.3)
15.62 (53376)
24
Negative
55
3275 (7220)
3453 (7612)
 
Engine Performance Data 50 Hz 60 Hz
Engine Speed rpm 1500  
Gross Engine Power Prime
Gross Engine Power Standby
BMEP Prime
kW (hp)
kW (hp)
kPa (psi)
997 (1337)
1105 (1482)
2610 (378.5)
 
BMEP Standby kPa (psi) 2892 (419.5)  

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kwIntroduction to other series of Wilson products
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kwBody details
Open unit series:
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Closed unit series:
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kwSupport customization according to needs
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Putting You in Control
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Whatever your power requirements, FG Wilson can provide a control system to suit your needs.   Our generator set experts design and validate FG Wilson control systems to optimise your generator set performance and put you in control.
All FG Wilson control panels are compact, versatile and easy to use. Our comprehensive range includes key-start analogue control panels for straightforward functionality and reliability; digital control panels suitable for use in mains failure applications, providing advanced metering, protection and diagnostics; and the next generation of advanced synchronising panels with integrated load management capability, suitable for synchronising up to 32 generator sets.
Our range of load transfer panels are designed to enhance the operation of your standby generator set in conjunction with our electronic control panels, to provide automatic control of your standby generator set in the event of a power outage, 24 hours a day, 365 days a year.
For more challenging power requirements, our Power Solutions Team is dedicated to the design and production of bespoke control systems to meet your individual needs, regardless of complexity.

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

Factory photos
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw
Applications
Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kwList of price models
model number Voltage, Frequency Prime Power Standby Power Engine Make Engine model Alternator Make Alternator model Fuel consumption
(L/h)
Dimensions
(mm)
Weight
KVA KW KVA KW  Prime  Standby Dry(kg)  Wet(kg)
P7.5-1S 230 V, 50 Hz 6.8 6.8 7.5 7.5 Perkins 403A-11G1 FG Wilson FGL10030 2.5 (0.7) 2.8 (0.7) 1550×620×1020 233 238
P7.5-4S 230 V, 50 Hz 6.8 6.8 7.5 7.5 Perkins 403D-11G FG Wilson FGL10030 2.5 (0.7) 2.8 (0.7) 1550×620×1020 233 238
240/120 V, 60 Hz 8 8 8.8 8.8 Perkins 403D-11G FG Wilson FGL10030 2.9 (0.8) 3.3 (0.9) 1550×620×1020 233 238
P9.5-1 400/230 V, 50 Hz 8.5 6.8 9.5 7.6 Perkins 403A-11G1 FG Wilson FGL10020 2.5 (0.7) 2.8 (0.7) 1550×620×1020 226 231
P9.5-4 400/230 V, 50 Hz 8.5 6.8 9.5 7.6 Perkins 403D-11G FG Wilson FGL10020 2.7 (0.7) 3 (0.8) 1550×620×1020 226 231
220/127 V, 60 Hz 10 8 11 8.8 Perkins 403D-11G FG Wilson FGL10020 2.9 (0.8) 2.9 (0.8) 1550×620×1020 226 231
P11-6S 230 V, 50 Hz 9.9 9.9 10.9 10.9 Perkins 403D-15G FG Wilson FGL10030 3.6 (1) 4 (1.1) 1550×620×1020 309 315
240/120 V, 60 Hz 11.8 11.8 12.9 12.9 Perkins 403D-15G FG Wilson FGL10030 4.3 (1.1) 4.8 (1.3) 1550×620×1020 309 315
P13.5-6 400/230 V, 50 Hz 12.4 9.92 13.5 10.8 Perkins 403D-15G FG Wilson FGL10020 3.6 (1) 4 (1.1) 1550×620×1020 302 308
220/127 V, 60 Hz 15 12 16.4 13.12 Perkins 403D-15G FG Wilson FGL10020 4.3 (1.1) 4.8 (1.3) 1550×620×1020 302 308
P14-6S 230 V, 50 Hz 13 13 14 14 Perkins 404D-22G1 FG Wilson FGL10040 4.3 (1.1) 4.6 (1.2) 1550×620×1020 370 377
240/120 V, 60 Hz 14.5 14.5 16 16 Perkins 404D-22G1 FG Wilson FGL10040 4.8 (1.3) 5.3 (1.4) 1550×620×1020 370 377
P16.5-1S 230 V, 50 Hz 15 15 16.5 16.5 Perkins 404A-22G1 FG Wilson FGL10060 5 (1.3) 5.6 (1.5) 1550×620×1020 378 385
P16.5-6S 230 V, 50 Hz 15 15 16.5 16.5 Perkins 404D-22G Leroy Somer LLB1114M 4.9 (1.3) 5.5 (1.5) 1500×620×1115 447 454
240/120 V, 60 Hz 17.6 17.6 19.4 19.4 Perkins 404D-22G Leroy Somer LLB1114M 5.7 (1.5) 6.3 (1.7) 1500×620×1115 447 454
P16-1 (skid) 400/230V, 50 Hz 14.5 11.6 16 12.8 Perkins  403A-15G2 Leroy Somer LL1114M 4.1 (1.1) 4.7 (1.2) 1500×860×895 333 339
P18-6 400/230 V, 50 Hz 16.5 13.2 18 14.4 Perkins 404D-22G1 FG Wilson FGL10040 4.4 (1.2) 4.8 (1.3) 1550×620×1020 365 372
220/127 V, 60 Hz 20 16 22 17.6 Perkins 404D-22G1 FG Wilson FGL10040 5.3 (1.4) 5.8 (1.5) 1550×620×1020 365 372
P22-1 400/230 V, 50 Hz 20 16 22 17.6 Perkins 404A-22G1 FG Wilson FGL10060 5.4 (1.4) 6.1 (1.6) 1550×620×1020 378 385
P22-6 (skid) 400/230V, 50 Hz 20 16 22 17.6 Perkins 404D-22G Leroy Somer LL1114M 5.3 (1.4) 5.9 (1.6) 1500×860×895 383 389
220/127V, 60 Hz 22.5 18 25 20 Perkins 404D-22G Leroy Somer LL1114M 5.8 (1.5) 6.5 (1.7) 1500×860×895 383 389
P26-3S 230 V, 50 Hz 24 24 26 26 Perkins 1103A-33G1 FG Wilson FGL20050-M 6.8 (1.8) 7.4 (2) 1570×760×1231 695 708
P26-6S 230 V, 50 Hz 24 24 26 26 Perkins 1103D-33G3 FG Wilson FGL20050-M 7.3 (1.9) 7.8 (2.1) 1570×760×1231 695 708
P33-3 400/230 V, 50 Hz 30 24 33 26.4 Perkins 1103A-33G1 FG Wilson FGL20030 6.9 (1.8) 7.7 (2) 1570×760×1231 660 673
P33-6 400/230 V, 50 Hz 30 24 33 26.4 Perkins 1103D-33G3 FG Wilson FGL20030 7.4 (2) 8.2 (2.2) 1570×760×1231 660 673
P50-3 400/230 V, 50 Hz 45 36 50 40 Perkins 1103A-33TG1 FG Wilson FGL20060 10.5 (2.8) 11.7 (3.1) 1680×760×1330 751 764
P50-5S 230 V, 50 Hz 45 45 50 50 Perkins 1103A-33TG2 FG Wilson FGL30030-M 12.6 (3.3) 14.1 (3.7) 1680×760×1330 864 887
P55-3 400/230 V, 50 Hz 50 40 55 44 Perkins 1103A-33TG2 FG Wilson FGL20070 11.6 (3.1) 12.8 (3.4) 1680×760×1330 756 769
P55-4 400/230 V, 50 Hz 50 40 55 44 Perkins 1104C-44TG2/3 FG Wilson FGL20070 15.9 (4.2) 17.4 (4.6) 1870×840×1333 818 831
P55-6S 230 V, 50 Hz 50 50 55 55 Perkins 1104D-44TG2/3 FG Wilson FGL30030-M 17.1 (4.5) 19.1 (5) 1870×840×1333 936 949
P65-5 400/230 V, 50 Hz 60 48 65 52 Perkins 1103A-33TG2 FG Wilson FGL20080 13.7 (3.6) 15 (4) 1680×760×1330 765 778
P65-6 400/230 V, 50 Hz 60 48 65 52 Perkins 1104D-44TG2/3 FG Wilson FGL20080 16.6 (4.4) 18.3 (4.8) 1870×840×1333 827 840
P88-3 400/230 V, 50 Hz 80 64 88 70.4 Perkins 1104A-44TG2 FG Wilson FGL30020 18.2 (4.8) 20.1 (5.3) 1870×840×1333 939 952
P88-6 400/230 V, 50 Hz 80 64 88 70.4 Perkins 1104D-E44TAG1 FG Wilson FGL30020 19.4 (5.1) 21 (5.5) 1980×890×1398 1068 1085
P90-3S 230 V, 50 Hz 82 82 90 90 Perkins 1104C-44TAG2 FG Wilson FGL30100-M 22.1 (5.8) 24.3 (6.4) 1980×890×1374 1151 1169
P90-6S 230 V, 50 Hz 81.7 81.7 89.8 89.8 Perkins 1104D-E44TAG2 FG Wilson FGL30100-M 23.6 (6.2) 24.9 (6.6) 1980×890×1374 1229 1246
P110-3 400/230 V, 50 Hz 100 80 110 88 Perkins 1104C-44TAG2 FG Wilson FGL30040 21.7 (5.7) 23.9 (6.3) 1980×890×1374 1019 1036
P110-6 400/230 V, 50 Hz 100 80 110 88 Perkins 1104D-E44TAG2 FG Wilson FGL30040 23.8 (6.3) 25.5 (6.7) 1980×890×1374 1136 1156
P150-5 400V, 50 Hz 135 108 150 120 Perkins 1106A-70TG1 Marelli MJB225LA4 29.9 (7.9) 33.4 (8.8) 2450×1010×1544 1407 1428
480V, 60 Hz 150 120 165 132 Perkins 1106A-70TG1 Marelli MJB225LA4 33.1 (8.7) 36.7 (9.7) 2450×1010×1544 1407 1428
P165-5 400V, 50 Hz 150 120 165 132 Perkins 1106A-70TAG2 Marelli MJB 250 MA4 32.4 (8.6) 35.1 (9.3) 2450×1010×1544 1545 1566
480V, 60 Hz 168.8 132 187.5 150 Perkins 1106A-70TAG2 Marelli MJB 250 MA4 37.9 (10.0) 41.6 (11.0) 2450×1010×1544 1545 1566
P200-3 400V, 50 Hz 180 144 200 160 Perkins 1106A-70TAG3 Marelli MJB 250 MB4 39.8 (10.5) 43.2 (11.4) 2510×1010×1640 1552 1579
480V, 60 Hz 200 160 218.8 175 Perkins 1106A-70TAG3 Marelli MJB 250 MB4 46.5 (12.3) 50.6 (13.4) 2510×1010×1640 1552 1579
P220-3 400/230 V, 50 Hz 200 160 220 176 Perkins 1106A-70TAG4 FG Wilson FGL30120 45.1 (11.9) 49 (12.9) 2510×1010×1640 1506 1522
P249-5-60Hz 480/277V, 60 Hz 225 180 250 200 Perkins 1506A-E88TAG2 Leroy Somer LL5114F 49.7 (13.1) 54.6 (14.4) 2662×1071×1818 1952 1985
P250-5 400/230 V, 50 Hz 230 184 250 200 Perkins 1506A-E88TAG2 Leroy Somer LL5114H 47.2 (12.5) 50.7 (13.4) 2662×1071×1818 2035 2068
P275-2 400/230 V, 50 Hz 250 200 275 220 Perkins 1506D-E88TAG4 Leroy Somer LL5114H 56.6 (15) 60.6 (16) 2662×1071×1818 2035 2068
P275-5 400/230 V, 50 Hz 250 200 275 220 Perkins 1506A-E88TAG3 Leroy Somer LL5114H 53.8 (14.2) 59.2 (15.6) 2662×1071×1818 2035 2068
P300-4 400/230 V, 50 Hz 275 220 300 240 Perkins 1506D-E88TAG4 FG Wilson FG26A230 60.2 (15.9) 64.3 (17) 2675×1071×1818 2077 2100
P300-5 400/230 V, 50 Hz 275 220 300 240 Perkins 1506A-E88TAG4 FG Wilson FG26A230 59 (15.6) 64.5 (17) 2675×1071×1818 2077 2100
P313-5-60Hz 480/277V, 60 Hz 281.3 225.04 312.5 250 Perkins 1506A-E88TAG3 Leroy Somer LL5114H 60.8 (16.1) 67.6 (17.9) 2662×1071×1818 2035 2068
P330-5 400/230 V, 50 Hz 300 240 330 264 Perkins 1506A-E88TAG5 FG Wilson FG26A250 62.8 (16.6) 70.1 (18.5) 2785×1071×1818 2228 2261
P344-5-60Hz 480/277V, 60 Hz 312.5 250 343.8 275.04 Perkins 1506A-E88TAG4 FG Wilson FG26A250 66.7 (17.6) 73.7 (19.5) 2785×1071×1818 2228 2261
P375-4-60Hz 480/277V, 60 Hz 343.8 275.04 375 300 Perkins 1506D-E88TAG4 FG Wilson FG26A250 73.3 (19.4) 80.5 (21.3) 2785×1071×1818 2228 2261
P375-5-60Hz 480/277V, 60 Hz 337.5 270 375 300 Perkins 1506A-E88TAG5 FG Wilson FG26A250 71.9 (19) 80.5 (21.3) 2785×1071×1818 2228 2261
P400-3-SA 400/230 V, 50 Hz 350 280 400 320 Perkins 2206A-E13TAG2 FG Wilson FG29A280 68.6 (18.1) 77.8 (20.6) 3800×1131×2156 3103 3161
P438-3-SA-60Hz 480/277V, 60 Hz 400 320 437.5 350 Perkins 2206A-E13TAG5 FG Wilson FG29A280 80.4 (21.2) 88.1 (23.3) 3800×1131×2156 3103 3161
P450-2-SA 400/230 V, 50 Hz 400 320 450 360 Perkins 2206D-E13TAG3A FG Wilson FG29A320 88.5 (23.4) 97.8 (25.8) 3800×1131×2156 3175 3233
P450-3-SA 400/230 V, 50 Hz 400 320 450 360 Perkins 2206A-E13TAG3 FG Wilson FG29A320 78.2 (20.7) 87.2 (23) 3800×1131×2156 3195 3253
P500-3-SA 400/230 V, 50 Hz 450 360 500 400 Perkins 2506A-E15TAG1 FG Wilson FG29A360 91.3 (24.1) 101.5 (26.8) 3800×1131×2215 3603 3661
P501-3-SA-60Hz 480/277V, 60 Hz 437.5 350 500 400 Perkins 2206A-E13TAG6 FG Wilson FG29A320 87.8 (23.2) 99.4 (26.3) 3800×1131×2156 3195 3253
P550-2-SA 400/230 V, 50 Hz 500 400 550 540 Perkins 2506D-E15TAG2 FG Wilson FG29A400 104 (27.5) 113.9 (30.1) 3787×1481×2193.4 3784 3832
P550-3-SA 400/230 V, 50 Hz 500 400 550 540 Perkins 2506A-E15TAG2 FG Wilson FG29A400 97.2 (25.7) 107.4 (28.4) 3800×1131×2215 3641 3699
P563-3-SA-60Hz 480/277V, 60 Hz 512.5 410 562.5 450 Perkins 2506A-E15TAG3 FG Wilson FG29A360 101.6 (26.8) 111.3 (29.4) 3800×1131×2215 3603 3661
P605-3 400/230 V, 50 Hz 550 440 605 484 Perkins 2806A-E18TAG1 FG Wilson FG33A450 107.4 (28.4) 119 (31.4) 3900×1461×2156 4134 4202
P625-3-SA-60Hz 480/277V, 60 Hz 568.8 455.04 625 500 Perkins 2506A-E15TAG4 FG Wilson FG29A400 112.8 (29.8) 123.2 (32.5) 3800×1131×2215 3641 3699
P660-3 400/230 V, 50 Hz 600 480 660 528 Perkins 2806A-E18TAG1A FG Wilson FG33A500 118.5 (31.3) 131.1 (34.6) 3900×1461×2156 4274 4342
P688-3-60Hz 480/277V, 60 Hz 625 500 687.5 550 Perkins 2806A-E18TAG1A FG Wilson FG33A500 124.6 (32.9) 138.2 (36.5) 3900×1461×2156 4274 4342
P715-3 400/230 V, 50 Hz 650 520 715 572 Perkins 2806A-E18TAG2 FG Wilson FG33A560 127.6 (33.7) 142 (37.5) 3900×1461×2156 4454 4522
P750-3-60Hz 480/277V, 60 Hz 681.3 545.04 750 600 Perkins 2806A-E18TAG3 FG Wilson FG33A500 138.9 (36.7) 155 (40.9) 3900×1461×2156 4274 4342
P780-1-SA 400/230 V, 50 Hz 706 564.8 780 624 Perkins 2806A-E18TTAG4 Leroy Somer LL7224J 144.2 (38.1) 160.6 (42.4) 4130×1690×2570 4869 4979
P813-1-SA-60Hz 480/277V, 60 Hz 750 600 812.5 650 Perkins 2806A-E18TTAG6A Leroy Somer LL7224H 160.7 (42.5) 176 (46.5) 4130×1690×2570 4724 4834
P850-1-SA 400/230 V, 50 Hz 770 616 850 680 Perkins 2806A-E18TTAG5 Leroy Somer LL7224L 160.3 (42.3) 179.9 (47.5) 4130×1690×2570 4930 5040
P895-1-SA-60Hz 480/277V, 60 Hz 812.5 650 895 710 Perkins 2806A-E18TTAG6A Leroy Somer LL7224J 172.8 (45.6) 192 (50.7) 4130×1690×2570 4869 4979
P938-1-60Hz 480/277V, 60 Hz 850 680 937.5 750 Perkins 2806A-E18TTAG7 Leroy Somer LL7224L 183.3 (48.4) 204.7 (54.1) 4130×1690×2570 4930 5040
P900-1 400/230 V, 50 Hz 800 640 892 713.6 Perkins 4006-23TAG3A FG Wilson FGL70030 172.9 (45.7) 195.5 (51.6) 4280×1731×2379 5818 5938
P1000-1 400/230 V, 50 Hz 910 728 1000 800 Perkins 4008TAG1A FG Wilson FGL70040 191.8 (50.7) 213.9 (56.5) 4788×2046×2419 7032 7145
P1001-1-60Hz 480/277V, 60 Hz 900 720 1000 800 Perkins 4008TAG1A Leroy Somer LL7224N 198.3 (52.4) 223.2 (59) 4788×2046×2419 7088 7201
P1100-1 400/230 V, 50 Hz 1000 800 1100 880 Perkins 4008TAG2A FG Wilson FGL70050 214 (56.5) 240 (63.4) 4788×2046×2419 7111 7224
P1101-1-60Hz 480/277V, 60 Hz 1000 800 1100 880 Perkins 4008TAG2A Leroy Somer LL7224P 221.2 (58.4) 244.4 (64.6) 4788×2046×2419 7137 7250
P1250-1 400/230 V, 50 Hz 1125 900 1250 1000 Perkins 4008-30TAG3 Leroy Somer LL8224H 240.1 (63.4) 266.3 (70.3) 4789×2197×2069 7613 7753
P1375-1 400/230 V, 50 Hz 1250 1000 1375 1100 Perkins 4012-46TWG2A Leroy Somer LL8224H 258 (68.2) 284.9 (75.3) 4788×1895×2440 8884 9080
480/277V, 60 Hz 1250 1000 1375 1100 Perkins 4012-46TWG2A Leroy Somer LL8224H 266 (70.3) 298 (78.7) 4788×1895×2440 8884 9080
P1500-1 400/230 V, 50 Hz 1350 1080 1500 1200 Perkins 4012-46TWG3A Leroy Somer LL8224L 279.2 (73.8) 313.4 (82.8) 4888×1895×2455 9247 9448
480/277V, 60 Hz 1350 1080 1500 1200 Perkins 4012-46TWG3A Leroy Somer LL8224L 289 (76.3) 324 (85.6) 4888×1895×2455 9247 9448
P1650-1 400/230 V, 50 Hz 1500 1200 1650 1320 Perkins 4012-46TAG2A Leroy Somer LL8224N 296.6 (78.4) 326.3 (86.2) 5044×2200×2461 10181 10388
P1875-1 400/230 V, 50 Hz 1700 1360 1875 1500 Perkins 4012-46TAG3A Leroy Somer LL9324F 349.7 (92.4) 390.2 (103.1) 5259×2192×2453 10997 11207
P2000-3 400/230 V, 50 Hz 1850 1480 2000 1600 Perkins 4016-61TRG1 Leroy Somer LL9324F 383.8 (101.4) 409.1 (108.1) 5839×2196×2605 12215 12528
P2250-3 400/230 V, 50 Hz 2000 1600 2250 1800 Perkins 4016-61TRG2 Leroy Somer LL9324H 418.1 (110.5) 470.8 (124.4) 5839×2196×2605 12215 12528
P2500-3 400/230 V, 50 Hz 2250 1800 2500 2000 Perkins 4016-61TRG3 Leroy Somer LL9324P 470.6 (124.3) 528.4 (139.6) 6038×2184×2900 12980 13380

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw  

 
Product Description


Document

ation

Operation and maintenance manual including circuit wiring diagrams.
Generator Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
Warranty
6.8 - 750 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760). For standby
applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.
730 - 2500 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760 hours) or 24
months from date of start-up, limited to 6000 hours. For standby applications the warranty period is 36 months from date of start-up, limited to 500 hours per year.
FG Wilson manufactures product in the following locations:
Northern Ireland • Brazil • China • India
With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
 

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby1250kVA/1000kw

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier