ISO8528-5 G2 Class Genset Diesel Generator Weichai 20kVA 40kVA 80kVA 100kVA

After-sales Service: Prime 12 Months From Date of Start-up
Warranty: Standby 24 Months From Date of Start-up
Type: Micro-Computer Control Automatic Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Oil Cooling
Samples:
US$ 4000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
80kw-100kva
Output Type
DC
Speed
Speed
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Automation Type
Excitation Mode
Static Exciter
Voltage, Frequency
400/230 V, 50 Hz
Power Factor
0.8
Phases
3
Regulation Class
ISO8528-5 G2
Transport Package
Moisture-Proof Film
Specification
40KW-50KVA
Trademark
WEICHAI
Origin
China
Production Capacity
5000 Sets Per Month

Product Description


Model: WEICHAI-PRP80KW-100KVA
 ISO8528-5 G2 Class Genset Diesel Generator Weichai 20kVA 40kVA 80kVA 100kVA 
Gen-set specifications
Model WPG110*1
Standby Rating  kVA/kWe 110/88
Prime Rating    kVA/kWe 100/80
Voltage V 400/230
Frequency  Hz 50
Power Factor 0.8(lagging)
No. of Phases 3
Fuel consumption@25%/ 50% / 75%(L/h) 5.94/10.57/13.95
Fuel consumption@100% / 110%(L/h) 18.15/20.52
Sound@1m(dB·(A)) Open≤105 dB(A); Silence ≤85 dB(A)
Ambient temp(ºC) -10~45
Gen-set regulation class ISO8528-5  G2
Steady-state voltage deviation ≤±2.5%;≤±5%
Transient voltage deviation                    (100%sudden power decrease/increase) +25%;-20%
Steady-state frequency band ≤1.5%
Transient frequency deviation from rated frequency (100%sudden power decrease/increase) +12%;-10%
 
Standard Features  
  ♦ Electronic governor ♦DC12 Electric starter ♦ Deep-sea DSE 6020 MK
♦ Closed water-cooled ♦ IP23 ♦H type insulation
♦ Air filter ♦ Muffler ♦ Circuit Breaker
♦Starting batteries      ♦ with connective wires ♦ Radiator
♦Oil Drain Valve ♦Forklift Groove ♦Shock Absorber
♦ Color Weichai blue (F)/beige canopy and black chassis (L)
♦ Packaging packing case(B,F)
 
 
Options  
  Voltage380V/415V     Voltage 440V/480V   External fuel tank(1000L/1500L)
Single Voltage 220V/230V Automatic Transfer Switch Alternator heater
Engine Heater (water) PMG/AREP  
 
Engine
 ISO8528-5 G2 Class Genset Diesel Generator Weichai 20kVA 40kVA 80kVA 100kVA
  1. Weichai WP4.1 series, 4 cylinder, in-line 4 stroke, radiator cooled engine
  2. Well-designed air handling system with
    • Dry type, Replaceable paper element air cleaner with restriction indicator
    • Air to air after cooling
    • Optimized turbocharger for increased altitude capabilities
    • High efficiency, large heat area intercooler, reduce the air temperature after the intercooler
  3. Fuel system with A1 class electronic governing
  4. Electrical starter motor with soft start engagement feature
  5. Intelligent fuel injection technology to start fast guarantee
  6. Battery charging alternator
  7. 1 x 12 V DC batteries
 
Alternator
 ISO8528-5 G2 Class Genset Diesel Generator Weichai 20kVA 40kVA 80kVA 100kVA
  1. Brushless type, Screen protected, Revolving field, Self excited alternator conforming to IS/IEC 60034-1
  2. Best in class efficiency
  3. Steel casing
  4. Compact design with sealed bearings for longer life and lesser maintenance
  5. IP23 standard protection level
  6. Impregnation on all wound components for better mechanical strength      

 
Control Module Specifications

The Deep-sea DSE 6020 MKIII is an Auto Mains Failure Control Module
  1. Back-lit LCD display
  1. 3 Phase generator and 3 Phase Mains monitoring
  1. Monitoring speed, frequency, voltage, current, oil pressure, coolant temperature and fuel level
  1. Display warning, shutdown and engine status information
  1. Hours counter provides accurate information for monitoring and maintenance
ISO8528-5 G2 Class Genset Diesel Generator Weichai 20kVA 40kVA 80kVA 100kVA
Engine specifications
Make WEICHAI
Mode WP4.1D100E200
Rated Speed r/min 1500
Prime Power kW 80
Cooling Liquid cooled
Governor Electronic
Aspiration Turbocharged and Aftercooled
No. of cylinders 4,in-line
Bore (mm) x Stroke (mm) 105*118
Displacement (L) 4.087
Fuel consumption@25%/ 50% / 75%(L/h) 6.05 / 10.65 / 15.44
Fuel consumption@100% / 110%(L/h) 18.9/21.4
Starting system 12VDC
Total lubrication system capacity (L) 21.7
Total coolant capacity (L) 13
Cooling fan airflow(m³/min) 190
Exhaust Temperature (°C) ≤550
Recommended air flow @ PRP (m³/min) 5.74
Exhaust back pressure (mBar) ≤50
Radiator design temperature(ºC) 50
Alternator specifications
Make WEICHAI  /  LEROY-SOMER
Alternator Frame WHA-100-4/0.4  / TAL A44 D
Exciter Type Self-excitation
Enclosure IP23
Voltage regulation ≤±1%
Class of Insulation H
Winding Pitch 2/3
Rotor Single bearing
Remarks
 
Prime power(PRP)
Prime power is defined as being the maximum power which a generating set is capable of delivering continuously while supplying a available electrical load when operated for an unlimited number of hours per year under the agreed operating conditions with the maintenance intervals and procedures being carried out as prescribed by the manufactures.
The permissible average power output, over 24h of operation shall not exceed 70% of the PRP unless otherwise agreed by the RIC engine manufacturer.
Emergency standby power(ESP)
       Emergency standby power is defined as the maximum power available during a available electrical power sequence, under the stated operating conditions, for which a generating set is capable of delivering in the event of a utility power outage or under test conditions for up to 200h of operation per year with the with the maintenance intervals and procedures being carried out as prescribed by the manufactures.
The permissible average power output, over 24h of operation shall not exceed 70% of the ESP unless otherwise agreed by the RIC engine manufacturer.

 
Standard Conditions
Standard operating environment: ambient temperature is 5ºC~40ºC,the altitude is less than 1000m,the relative humidity is less than 90%(25ºC),and there is no dust, sand dust, salt fog, mold, condensation environment, etc.
If the operating environment exceeds the above requirements, please contact the factory and consult.

 
Typical Enclosed Genset Dimensions
Genset Model Prime Rating
(kVA)
Length A(mm) Width
B(mm)
Height C(mm) Wet Weight*
(kg)
Standard Fuel tank
Capacity (L)
WPG110F1 80 1930 860 1218 1140 105
WPG110L1 80 2880 1050 1600 1690 180
 
 *:Include coolant and oil

             Open genset                                                                                                                               Enclosed gensetISO8528-5 G2 Class Genset Diesel Generator Weichai 20kVA 40kVA 80kVA 100kVA

Beijing Xinda Creation Machinery Equipment Co., Ltd. Specialized in production and sales of diesel generator sets, reefer container generator, mobile lighting tower, solar suveilliance system. Also providing Hydraulic Hammer/Breaker.

FAQ

  1.Q :What's the MOQ. Can I get a sample of free?
      A : MOQ, according to the actual situation.
      We can offer a sample of free. Please, friendly bear the shipping cost.
   2.Q : When can i get the quotation?
      A : We usually quote within 24 hours after getting your detailed requirements, like size, quantity, etc.
   3.Q : What is your payments terms?
      A : We can accept 30% deposit, 70% balance to be against the BL copy or by LC, or other payment terms.
   4.Q : What is your terms of delivery?
      A : We accept FOB, CFR, CIF, EXW, etc. You can choose the most convenient way for 
      you. Besides that, we can also shipping by Air and Express. 


CONTACT

Matt  Big client manager

If you are interested in our products or have any doubts,Please

Send your Inquiry Detaill, Click "Contact Now" !

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
21000000 RMB
Plant Area
101~500 square meters