• Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
  • Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
  • Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
  • Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
  • Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
  • Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent

Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent

After-sales Service: Dedicated After-Sales Service Department
Warranty: 12 Months
Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Six Stroke
Cooling Method: Water Cooling
Samples:
US$ 5810/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
P7.5-4S
Output Type
AC Single Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Voltage, Frequency
230 V, 50 Hz/240/120 V, 60 Hz
Weight
Dry:233 (514)Kg/Wet 238 (525) Kg
Engine Make
Perkins
Circuit Breaker Type: 3 Pole MCB
3 Pole MCB
Transport Package
Shipping Containers
Specification
L1550 (61)mm*W620 (24.4)mm*H1020 (40.2)
Trademark
FG WILSON
Origin
China
Production Capacity
50000

Product Description

Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
Engine Make   Perkins
Engine Model:   403D-11G
Alternator Make   FG Wilson
Alternator Model:   FGL10030
Control Panel:   FG100
Base Frame:   Heavy Duty Fabricated Steel
Circuit Breaker Type:   3 Pole MCB
Frequency:   50 HZ 60 HZ
Engine Speed: RPM rpm 1500 1800
Fuel Tank Capacity: litres (USgal)  
Fuel Consumption Prime litres (USgal)/hr 2.5 (0.7) 2.9 (0.8)
Fuel Consumption Standby litres (USgal)/hr 2.8 (0.7) 3.3 (0.9)
Engine Technical Data
No. of Cylinders
Alignment
Cycle
Bore
Stroke
Induction
Cooling Method
Governing Type
Governing Class
Compression Ratio
Displacement
Moment of Inertia:
Voltage
Ground
Battery Charger Amps
Engine Weight Dry
Engine Weight Wet



mm (in)
mm (in)






L (cu. in)
kg  (lb/in²)



kg (lb)
kg (lb)
3
IN LINE
4 STROKE
77 (3)
81 (3.2)
NATURALLY ASPIRATED
WATER
MECHANICAL
ISO 8528
23:1
1.1 (69)
1.63 (5570)
12
Negative
40
129 (284)
139 (306)
 
Engine Performance Data 50 Hz 60 Hz
Engine Speed rpm 1500 1800
Gross Engine Power Prime kW (hp) 8.6 (12) 10.7 (14)
Gross Engine Power Standby kW (hp) 9.5 (13) 11.8 (16)
BMEP Prime kPa (psi) 610 (88.5) 630 (91.4)
BMEP Standby kPa (psi) 672 (97.4) 695 (100.8)
 
Fuel Filter Type:     Replaceable Element
Recommended Fuel:   Class A2 Diesel
Fuel Consumption at   110 % Load 100 % Load 75 % Load 50 % Load
50 Hz Prime: l/hr (USgal/hr) 2.8 (0.7) 2.5 (0.7) 1.9 (0.5) 1.5 (0.4)
50 Hz Standby l/hr (USgal/hr) - 2.8 (0.7) 2.1 (0.6) 1.6 (0.4)
60 Hz Prime l/hr (USgal/hr) 3.3 (0.9) 2.9 (0.8) 2.2 (0.6) 1.8 (0.5)
60 Hz Standby l/hr (USgal/hr) - 3.3 (0.9) 2.4 (0.6) 1.8 (0.5)
(Based on diesel fuel with a specific gravity of 0.84 and conforming to BS2869,class A2
 
Air System 50 Hz 60 Hz
Air Filter Type:   Replaceable Element
Combustion Air Flow Prime
Combustion Air Flow Standby
Max. Combustion Air Intake Restriction
m³/min (cfm)
m³/min (cfm)
kPa
0.7 (25)
0.7 (25)
6.4 (25.7)
0.9 (32)
0.9 (32)
6.4 (25.7)
 
Air System 50 Hz 60 Hz
Air Filter Type:   Replaceable Element
Combustion Air Flow Prime
Combustion Air Flow Standby
Max. Combustion Air Intake Restriction
m³/min (cfm)
m³/min (cfm)
kPa
0.7 (25)
0.7 (25)
6.4 (25.7)
0.9 (32)
0.9 (32)
6.4 (25.7)
*: Heat radiated from engine and alternator
Designed to operate in ambient conditions up to 50°C (122°F).
Contact your local FG Wilson Dealer for power ratings at specific site conditions.
 
Lubrication System
Oil Filter Type:   Spin-On, Full Flow
Total Oil Capacity:
Oil Pan Capacity:
Oil Type:
l (USgal)
l (USgal)
4.9 (1.3)
4.4 (1.2)
API CH4 15W-40
Oil Cooling Method:   N/A
 
Exhaust System   50 Hz 60 Hz
Maximum Allowable Back Pressure: kPa (inHg) 10.2 (3) 10.2 (3)
Exhaust Gas Flow: Prime m³/min (cfm) 1.7 (59) 2.2 (78)
Exhaust Gas Flow: Standby m³/min (cfm) 1.8 (64) 2.4 (85)
Exhaust Gas Temperature: Prime °C (°F) 368 (694) 437 (819)
Exhaust Gas Temperature: Standby °C (°F) 420 (788) 515 (959)
 
Alternator Physical Data
No. of Bearings: 1
Insulation Class:
Winding Pitch:
Winding Code
Wires:
Ingress Protection Rating:
Excitation System:
AVR Model:
H
2/3
M
3
IP23
SHUNT
R121
* dependant on voltage code selected
Alternator Operating Data
Overspeed: rpm 2250
Voltage Regulation: (Steady state) Wave Form NEMA = TIF:
Wave Form IEC = THF:
Total Harmonic content LL/LN:
Radio Interference:
Radiant Heat: 50 Hz
Radiant Heat: 60 Hz
%

%
%

kW (Btu/min)
kW (Btu/min)
+/- 1.0
100
2
3.5
EN61000-6
1.4 (80)
1.6 (91)
 
Alternator Performance Data 50 Hz:

Voltage Code
240 V 230 V 220 V  
Motor Starting Capability* Short Circuit Capacity**
Reactances
kVA
%
Xd
X'd
X"d
18
0
1.15
0.21
0.116
17
0
1.25
0.23
0.116
16
0
1.36
0.25
0.126

0
 

Voltage Code
 

220/110 V


240/120 V
   
Motor Starting Capability* Short Circuit Capacity**
Reactances
kVA
%
Xd
X'd
X"d

0
14
0
1.92
0.36
0.179
16
0
1.62
0.3
0.15
0
0
0
0
0

0
Reactances shown are applicable to prime ratings.
*Based on 30% voltage dip at 0.9 power factor.
** With optional independant excitation system (PMG / AUX winding)
 
Output Ratings 50 Hz

Voltage Code
415/240V
400/230V
380/220V
230/115V
220/127V
220/110V
200/115V

kVA
Prime
kW

kVA
Standby
kW
240V 6.8 6.8 7.5 7.5
230V 6.8 6.8 7.5 7.5
220V 6.8 6.8 7.5 7.5
Output Ratings 60 Hz

Voltage Code
480/277V
440/254V
416/240V
400/230V
380/220V
Prime
kVA
Standby
kW                                             kVA

kW
240/139V
240/120V
230/115V
220/127V
220/110V
208/120V
240/120 8 8 8.8 8.8
220/110 8 8 8.8 8.8


Wilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and SilentWilson Open Type Small Diesel Generator Sets 230 V, 50 Hz/240/120 V, 60 Hz Standby7.5kVA/7.5kw and 8.8/8.8. Open and Silent
 