• Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
  • Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw

After-sales Service: Dedicated After-Sales Service Department
Warranty: 12 Months
Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Samples:
US$ 98000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
P660-3
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Voltage, Frequency
400/230 V, 50 Hz
Weight
Dry: 4274 (9423) Kg / Wet: 4342 (9572) Kg
Engine Make
Perkins
Circuit Breaker Type: 3 Pole MCB
3 Pole MCCB
Transport Package
Shipping Containers
Specification
L3900 (153.5)mm*W1461 (57.5)mm*H2156 (84.9)
Trademark
FG WILSON
Origin
China
Production Capacity
50000

Product Description

 

  Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw             
Engine Make   Perkins
Engine Model:   2806A-E18TAG1A
Alternator Make   FG Wilson
Alternator Model:   FG33A500
Control Panel:   FG100
Base Frame:   Heavy Duty Fabricated Steel
Circuit Breaker Type:   3 Pole MCCB
Frequency:   50 HZ 60 HZ
Engine Speed: RPM rpm 1500  
Fuel Tank Capacity: litres (USgal) 1132 (299.04)
Fuel Consumption Prime litres (USgal)/hr 118.5 (31.3)  
Fuel Consumption Standby litres (USgal)/hr 131.1 (34.6)  
 
Engine Technical Data
No. of Cylinders
Alignment
Cycle
Bore
Stroke
Induction
Cooling Method
Governing Type
Governing Class
Compression Ratio
Displacement
Moment of Inertia:
Voltage
Ground
Battery Charger Amps
Engine Weight Dry
Engine Weight Wet



mm (in)
mm (in)






L (cu. in)
kg  (lb/in²)



kg (lb)
kg (lb)
6
IN LINE
4 STROKE
145 (5.7)
183 (7.2)
TURBOCHARGED AIR TO AIR CHARGE COOLED
WATER
ELECTRONIC
ISO 8528 G2
14.5:1
18.1 (1104.5)
7.05 (24091)
24
Negative
70
2050 (4519)
2158 (4758)
 
Engine Performance Data 50 Hz 60 Hz
Engine Speed rpm 1500  
Gross Engine Power Prime
Gross Engine Power Standby
BMEP Prime
kW (hp)
kW (hp)
kPa (psi)
539.7 (724)
592.7 (795)   2381 (345.4)
 
BMEP Standby kPa (psi) 2615 (379.3)  

 Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kwWilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
Output Ratings 50 Hz
    Prime Standby  
Voltage Code kVA kW kVA kW
415/240V 600 480 660 528
400/230V 600 480 660 528
380/220V 593.8 475.04 660 528
230/115V
220/127V
220/110V
200/115V
600 480 660 528
240V
230V
220V
 
Output Ratings 60 Hz

Voltage Code
480/277V
440/254V
416/240V
400/230V
380/220V
Prime
kVA
Standby
kW                                             kVA

kW
240/139V
240/120V
230/115V
220/127V
220/110V
208/120V
240/120
220/110

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
Product Description

Document

ation

Operation and maintenance manual including circuit wiring diagrams.
Generator Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
Warranty
6.8 - 750 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760). For standby
applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.
730 - 2500 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760 hours) or 24
months from date of start-up, limited to 6000 hours. For standby applications the warranty period is 36 months from date of start-up, limited to 500 hours per year.
FG Wilson manufactures product in the following locations:
Northern Ireland • Brazil • China • India
With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
To contact your local Sales Office please visit the FG Wilson website at www.fgwilson.com.
FG Wilson is a trading name of Caterpillar (NI) Limited.
In line with our policy of continuous product development, we reserve the right to change specification without notice.

Wilson Open Type Medium Diesel Generator Sets 400/230 V, 50 Hz Standby660kVA/528kw
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
21000000 RMB
Plant Area
101~500 square meters