• Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
  • Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
  • Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
  • Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
  • Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
  • Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw

Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw

After-sales Service: Dedicated After-Sales Service Department
Warranty: 12 Months
Type: Self-Starting Diesel Generator
Installation Method: Fixed
Stroke: Four Stroke
Cooling Method: Water Cooling
Samples:
US$ 44000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2022

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
  • Overview
  • Product Description
Overview

Basic Info.

Model NO.
P249-5
Output Type
AC Three Phase
Speed
HSS
Conditions of Use
Land Use
Usage
Common Units, Standby Unit, Emergency Crew
Landuse Type of Unit
Low Noise Automation Type
Excitation Mode
AC Rotating Exciter
Voltage, Frequency
480/277V, 60 Hz
Weight
Dry:1952 (4303)Kg / Wet:1985 (4376)Kg
Engine Make
Perkins
Circuit Breaker Type: 3 Pole MCB
3 Pole MCCB
Transport Package
Shipping Containers
Specification
L2662 (104.8)mm*W1071 (42.2)mm*H1818 (71.6)
Trademark
FG WILSON
Origin
China
Production Capacity
50000

Product Description

 

Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw     
Engine Make   Perkins
Engine Model:   1506A-E88TAG2
Alternator Make   Leroy Somer
Alternator Model:   LL5114F
Control Panel:   Power Wizard 1.1+
Base Frame:   Heavy Duty Fabricated Steel
Circuit Breaker Type:   3 Pole MCCB
Frequency:   50 HZ 60 HZ
Engine Speed: RPM rpm   1800
Fuel Tank Capacity: litres (USgal) 528 (139.48)
Fuel Consumption Prime litres (USgal)/hr   49.7 (13.1)
Fuel Consumption Standby litres (USgal)/hr   54.6 (14.4)
  
    
Engine Technical Data
No. of Cylinders
Alignment
Cycle
Bore
Stroke
Induction
Cooling Method
Governing Type
Governing Class
Compression Ratio
Displacement
Moment of Inertia:
Voltage
Ground
Battery Charger Amps
Engine Weight Dry
Engine Weight Wet



mm (in)
mm (in)






L (cu. in)
kg  (lb/in²)



kg (lb)
kg (lb)
6
IN LINE
4 STROKE
112 (4.4)
149 (5.9)
TURBOCHARGED AIR TO AIR CHARGE COOLED
WATER
ELECTRONIC
ISO 8528 G2
16.1:1
8.8 (537)
2.4031 (8212)
24
Negative
45
778 (1715)
800 (1764)
       
    
Engine Performance Data 50 Hz 60 Hz
Engine Speed rpm   1800
Gross Engine Power Prime
Gross Engine Power Standby
BMEP Prime
kW (hp)
kW (hp)
kPa (psi)
  211.3 (283)
233.9 (314) 1600 (232)
BMEP Standby kPa (psi)   1771 (256.8)
    

 

Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kwWilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw 
Engine Performance Data 50 Hz 60 Hz
Engine Speed rpm   1800
Gross Engine Power Prime
Gross Engine Power Standby
BMEP Prime
kW (hp)
kW (hp)
kPa (psi)
  211.3 (283)
233.9 (314) 1600 (232)
BMEP Standby kPa (psi)   1771 (256.8)
 
Output Ratings 60 Hz
    Prime Standby  
Voltage Code kVA kW kVA kW
480/277V 225 180 250 200
440/254V
416/240V
400/230V
225 180 250 200
380/220V 197.9 158.3 217.7 174.16
240/139V
240/120V
230/115V
225 180 250 200
220/127V
220/110V
208/120V
225 180 250 200
240/120
220/110

Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
Product Description

Documentation

Operation and maintenance manual including circuit wiring diagrams.
Generator Set Standards
The equipment meets the following standards: BS5000, ISO 8528, ISO 3046, IEC 60034, NEMA MG-1.22.
Warranty
6.8 - 750 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760). For standby
applications the warranty period is 24 months from date of start-up, limited to 500 hours per year.
730 - 2500 kVA electric power generation products in prime applications the warranty period is 12 months from date of start-up, unlimited hours (8760 hours) or 24
months from date of start-up, limited to 6000 hours. For standby applications the warranty period is 36 months from date of start-up, limited to 500 hours per year.
FG Wilson manufactures product in the following locations:
Northern Ireland • Brazil • China • India
With headquarters in Northern Ireland, FG Wilson operates through a Global Dealer Network.
To contact your local Sales Office please visit the FG Wilson website at www.fgwilson.com.
FG Wilson is a trading name of Caterpillar (NI) Limited.
In line with our policy of continuous product development, we reserve the right to change specification without notice.

Wilson Open Type Medium Diesel Generator Sets 480/277V, 60 Hz Standby250kVA/200kw
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now